It is an ideal testing tool for the physical changes of electronic and electrical components, metals, chemical materials, automation components, communication components, defense industry, aerospace industry, BGA, PCB substrates, electronic chip IC, semiconductor ceramics and polymer materials. An ideal testing tool for physical changes of components, metals, chemical materials, automation components, communication components, defense industry, aerospace industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramics and polymer materials.
Performance indicators meet the requirements of GB5170, 2, 3, 5, 6-95 "Environmental Test Basic Parameter Verification Method high Temperature, constant humidity and Heat, alternating humidity and heat test equipment" Environmental testing procedures test B: High temperature test method GB 2423.2-89 (IEC68-2-2) Environmental testing procedures - Test Ca: Constant damp heat test method GB/T 2423.3-93 (IEC68-2-3) Environmental test specification test Da: Alternating humid heat test method GB/T423.4-93(IEC68-2-30) |
technical parameter: | |||
1.Product name | Three-Chamber thermal shock test chamber | ||
2. Brand and product model | E003 | ||
3. Test method | Pneumatic damper switches 3 temperature zones, water-cooled | ||
4. Sample limit | This test equipment prohibits: 1. Test and storage of samples of flammable, explosive and volatile substances 2. Test and storage of corrosive material samples 3. Testing or storage of biological samples 4. Test and storage of strong electromagnetic emission source samples 5. Testing and storage of radioactive material samples 6. Test and storage of samples of highly toxic substances 7. Testing and storage of samples that may produce highly toxic substances during testing or storage |
||
5. Volume and size | |||
5.1 High temperature setting range | +60ºC~+200ºC | ||
5.2 High temperature shock temperature | +150ºC | ||
5.3 Low temperature setting range | -10ºC~-55ºC(Optional, -40ºC) | ||
5.4 Low temperature shock temperature | -550ºC | ||
5.5 High and low temperature impact range | -55ºC~+150ºC | ||
5.6 Warm-up time | +20~+200ºC,≤60min | ||
5.7 Pre-cooling time | +20~-55ºC,≤80min | ||
5.8 High and low temperature air door switching time (turning box time) | High temperature tank←→Low temperature tank, within 3 seconds | ||
5.9 Impact temperature arrival time (temperature change time) | ≤5min | ||
5.10 Rising and falling temperature overshoot | ≤±3ºC | ||
5.11 Pre-cooling and pre-heating box temperature recovery time | ≤30min | ||
5.12 Load (plastic IC) | 10KG | ||
5.13 Compressor selection | France Taikang Germany Boke | ||
5.14 Temperature fluctuation | ±0.5ºC | ||
5.15 Temperature deviation | <=±2ºC | ||
5.16 Temperature uniformity | <=±2ºC | ||
5.17 inches | Inner Size | External Size | |
5.18 Volume (80L)(Optional 50L, 150L, 225L, 408L) | 40x50x40(WxHxD)CM | 150x175x165(WxHxD)CM | |
5.19 Power and net weight | Power:22KW | Voltage: 380V50Hz three-phase four-wire + protective ground wire | Weight: 1500KG |
Q: How is your service?
Q: Are you able to provide a ISO 17025 calibration certificate?
A: Yes, we generally provide two calibration certificates(optional).
• ISO 17025 certificate provided by a third party inspection company with charges.
• Calibration certificate provided by UTS without charges.
Q: Can you send report of fumigation report?
A: Our packing is composite board, not log, so it do not need fumigation treatment.
Thank You For Always Supporting UTS Products!